TraceTek alarm modules & panels
The modules that raise the alarm, show where the leak is and tell your building systems, from one machine to a whole site.

Raychem TraceTek alarm and locating modules monitor the sensing cable and probes. The TTC-1 is a simple alarm for up to 76 m of cable. The TTSIM-3 and TTSIM-4 locate the leak on up to 350 m and 1,500 m of cable, switch up to two programmable relays and report to a PLC or host system over RS-485 using standard protocols. The TT-TS12B touchscreen panel brings up to 250 circuits together and shows each leak on a floor plan, piping layout or equipment photo.
What each level does
TTC-1
Red LED and relay contacts for one machine, tank or sump.
TTSIM-3
Locates leaks on up to 350 m of cable.
TTSIM-4
Locates leaks on up to 1,500 m of cable.
BMS connection
RS-485 serial up to 1,200 m; TTSIM-1/1A/2 support Modbus, Opto 22 and Metasys.
TT-TS12B panel
12" touchscreen, up to 250 circuits, 5,000-event memory.
Alarm outputs
Audible alarm, summary relays, serial data and web interface on the panel.
Which fits your site
One machine
TTC-1 on an air-handling unit, pump or tank.
A plant room
A TTSIM module with its own relays.
A data center
TTSIM modules networked to a TT-TS12B panel.
A building with a BMS
TTSIM modules reporting to the BMS over RS-485.
Modules and panels
From a single alarm relay on one machine to a touchscreen map of a whole building.

TTC-1 alarm module
Up to 76 m of cable. Red LED and relay contacts, without location display: a low-cost choice for one machine or tank.

TTSIM-3 / TTSIM-4
Up to 350 m (TTSIM-3) or 1,500 m (TTSIM-4) of cable, with programmable relays, RS-485 and optional Bluetooth.

TTSIM-1A / TTSIM-2
Earlier 150 m modules, the TTSIM-2 with an LCD showing the leak location. TTSIM-3/4 are their direct replacements.

TT-TS12B touchscreen panel
A 12" touchscreen for up to 250 circuits, showing each leak on a floor plan, piping layout or equipment photo.
Product images: Raychem (Chemelex).
Swipe to see all →How a project runs
Survey
A site visit or drawing review to identify the risk areas.
Design & quotation
Cable routes, zones and module locations, with an itemised quotation.
Supply
Genuine Raychem TraceTek materials supplied as an official partner.
Installation
Cable, probes and modules installed by our team.
Commissioning
Each zone tested with liquid and the alarm path verified.
Support
Training for your staff and maintenance on request.
Common questions
Can the system report to our BMS?
Yes. TTSIM modules report to a PLC or host system over RS-485 using standard protocols; the earlier TTSIM-1/1A/2 use Modbus, Opto 22 or Metasys. We confirm the protocol for your BMS during design.
Can it shut off a valve automatically?
The module relays can switch an alarm or a motorised valve. What is suitable for your site is confirmed during design.
We have older TTSIM-1A or TTSIM-2 modules. Can they be replaced?
Yes. TTSIM-3/4 are the direct replacements for TTSIM-1, 1A and 2.
What does the touchscreen panel show?
Each detection circuit, with the leak location on a floor plan, piping layout or photo of the equipment.
Who supplies Raychem TraceTek in Egypt?
Teknetic is an official Raychem partner in Egypt and handles survey, design, supply, installation, commissioning and maintenance.